OxiSure

3,499.00 1,999.00

The fingertip pulse oximeter produced by our company is a kind of noninvasive and continuous medical instrument for detecting the arterial oxygen saturation and pulse rate of human body. It is portable and can accurately and rapidly measure the blood oxygen, so that you know whether you are lack of oxygen at present.

Product Feature
• The product adopts two-color LCD display, and the interface can display six
• different display modes;
• The power consumption of the product is low, and the two AAA batteries can last
• for more than 40 hours;
• There is a low voltage warning in dication when the battery vdtage is too low, which
• may affect normal use;
• When no signal is generated, the product will enter standby mode after 8 seconds
• Small size, light weight, easy to carry.

Add to WishlistAdd to Compare
Category:

Model number : IT-OX02
Model name: OxiSure

The fingertip pulse oximeter produced by our company is a kind of noninvasive and continuous medical instrument for detecting the arterial oxygen saturation and pulse rate of human body. It is portable and can accurately and rapidly measure the blood oxygen, so that you know whether you are lack of oxygen at present.

Product Feature
• The product adopts two-color LCD display, and the interface can display six
• different display modes;
• The power consumption of the product is low, and the two AAA batteries can last
• for more than 40 hours;
• There is a low voltage warning in dication when the battery vdtage is too low, which
• may affect normal use;
• When no signal is generated, the product will enter standby mode after 8 seconds
• Small size, light weight, easy to carry.

Summary :
Blood Oxygen saturation is the percentage of oxygen-bound hemoglobin (HbO2) in the blood as a percentage of the total binding hemoglobin (Hb).That is, the concentration of oxygen in the blood, reflecting the saturation of oxyhemoglobin in the blood. It is a very important physiological parameter of the respiratory and circulatory system. Many respiratory diseases can cause oxygen desaturation. In addition, the automatic regulation of the body caused by anesthesia, major surgical trauma and some injuries caused by medical examinations may cause problems in the oxygen supply of patients and reduce blood oxygen saturation, resulting in some adverse reactions such as dizziness, vomiting, weakness and other symptoms. If treatment is not taken in time, serious cases will endanger the life of patients. Therefore, timely understanding of the patient’s blood oxygen saturation is helpful for doctors to find out the problem in time, which is of great significance in the field of clinical medicine

The fingertip pulse oximeter (hereinafter referred to as the oximeter) has the advantages of small volume, low power consumption, simple operation and convenient carrying. When measuring, just put your finger into the finger clamp photoelectric sensor, the device collects data through a photosensitive detector, and then displays the measurement results on the indicator. The clinical test shows that the oximeter has high accuracy and repeatability

Principle of measurement
The measurement principle of the oximeter is based on the spectral characteristics of hemoglobin and oxygenated hemoglobin with different absorption rates in red and infrared light regions, and “Lamnert Beer” law is used to establish empirical formulas for data
The working principle of the instrument is the photoelectric blood oxygen detection technology combined with volume pulse trace technique, using two different wavelengths of light (660 nm red and near-infrared light of 940 nm) by absorbing the perspective to sensor illuminate human fingernails and by the light sensor for measuring signal, the access to information through electronic circuit and display on the LCD screen after the microprocessor, convenient to read

It is composed of doubleHayer components and photoelectric detector. Bone, cell tissue, pigmentation and vein vessels all have different absorption constants of light. When the artery pulsates with the heart’s contraction and relaxation, the absorption of light will be different with the increase and decrease of blood flow. The absorptivity of different light during diastole and contraction of the heart is transformed into the measurement result of blood oxygen saturation This measurement is the oxygen saturation. Schematic diagram of operation
1. Infrared receiver tube
2. Infrared emission tube

1. Infrared receiver tube 2. Infrared emission tube

Safety Requirements
• Not shared with MRI or CT equipment
• Explosion hazard: do not use this instrument in the environment of flammable anesthetic gas.
• Blood oxygen instrument only plays an auxiliary role in the diagnosis of the patient, ask the doctor to make a diagnosis based on the clinical manifestations and symptoms.
• The oximeter sensor test site should be checked frequently to confirm that the skin of the patient at the sensor test site is intact and circulatory.
• The fingertip pulse oximeter sensor is not suitable for contact with the adhesive tape, which may result in incorrect measurements or mistaken skin blisters.
• Please read this manual carefully before use.
• Blood oxygen meter has no function of blood oxygen indication, but it can not be used as a continuous monitor for a long time.
• When using for a long time, please change the test point periodically according to the different situation of the patient. The test point must be replaced and the skin integrity, circulation and correct adjustment must be made every 2 hours at most
• High pressure disinfection, vinyl oxide disinfectant, or immersion of sensors in liquid disinfectant can cause false readings.
• Disorders of important indicators of hemoglobin, such as carbohemoglobin or methemoglobin, can cause incorrect readings.
• Excessive intravascular staining, such as indocyanine green or methylene blue, can cause incorrect readings.
• The measurement accuracy of blood oxygen saturation will be affected by the bright light of the surrounding environment.
• (e.g, disinfection wipes or direct sunlight) add a protective case to the sensor if necessary.
• The patient’s unexpected movements can cause false readings.
• Interference with a medical high frequency signal or defibrillator can cause false readings.
• The rhythmic beating of the veins can cause false readings.
• The sensor’s position in the same artery or blood vessel as the blood pressure cuff can cause a false reading Patients with low blood pressure, severe low systolic blood pressure, severe anemia, or hypothermia can cause false readings
• Taking a cardiac stimulant after a patient’s heart has stopped beating or if the patient is shaking can cause a false reading
• Bright nails or nail polish coated nails cause erroneous readings..

*
The recyclable accessories or components of accessories in the equipment specified in the manual, including batteries, shall comply with local laws and regulations

Product scope of application
The pulse oximeter can detect the blood oxygen saturation and pulse rate of human body through fingers. This product is suitable for family, hospital, oxygen bar, sports health care (before and after sports, not recommended in the process of sports), community medical treatment, etc. It is applicable to plateau tourism, mountaineering enthusiasts, patients (patients who have been at home for a long time or are in emergency state), the elderly over 60 years old, people who work more than 12 hours a day, sportsmen (professional sports training or sports enthusiasts), workers in closed environment, etc. This product is not suitable.

Method of application
1. Install two AAA batteries according to the positive and negative marks of the battery compartment and directly fasten the battery cover (no need to press the self-locking button again);
2. Insert the finger into the rubber hole (it is better to fully extend the finger), with the nail facing up, and then release the clip;
3. Press the button in the middle of the front panel to start the oximeter for blood oxygen detection;
4. In the process of use, it is better not to shake your fingers, and the human body should not be in motion ;
5. If you want to change the direction of the display during use, press the button in the middle of the front panel
6. Read relevant data directly from the display:
7. The instrument has sleep function, no signal generation will enter standby sleep state;
8. When the battery power is low, the LCD will display a low battery indicator, prompting the user to replace the battery

Fingernails must be up when inserting fingers
Declaration: before using this product for testing, please use medical alcohol to wipe the rubber of finger sleeve first, and use medical alcohol to wipe the tested finger before and after using. (the rubber material is medical rubber, which is non-toxic, harmless and has no side effects such as allergy to human skin.)

Technical Specifications
1 Display mode: LCD two color display
2 Blood oxygen saturation: measurement range : 70% -99% Measurement accuracy: within the range of 70% ~ 99% + 2%, s 70%,
no definition of accuracy Resolution: blood oxygen saturation 1%
3 Pulse rate: measurement range : 30BPM-240BPM Measurement accuracy: 1BPM or + 1% of the measured value (take the
larger value)
4 Battery model: 2 AAA 1.5V alkaline batteries;
5 Power consumption: less than 30mA
6 Automatic shutdown: automatically shutdown after 8 seconds without finger insertion
7 Boundary dimension : 58mmx 36mmx 33mm
8 environmental conditions : usage temperature : 5°C ~ 40°C
Storage temperature : -10°C ~ 40°C Environmental humidity: 10% -80% storage when working at 15% – 80%
Atmospheric pressure : 70kPa -106kPa
9 Statement. This product E MC follows iec60601-1-1-2 standard.
10 Pulse wave measurement sensitivity under weak perfusion conditions: the required test
equipment (BIO-TEK INDEX pulse oximeter) can measure the available pulse wave
signal with amplitude of 6% of the simulated pulse wave signal amplitude
11 Anti-interference ability of ambient light the BIO-TEK INDEX pulse oximeter was used to
test interference signal, and the instrument could work normally

Product classification :
1 According to the medical equipment management into categories: II such equipment
2 According to the type of shock protection: internal power equipment
3 According to the degree of anti-electric shock: BF type

Maintenance and preservation
1 When the low voltage indicator is on, please replace the battery immediately
2 Clean the surface of the oximeter before giving it to the patient
3 If you do not use the oximeter for a long time, please take out the battery inside
4 This product is best stored in an environment with an ambient temperature of – 10 to 40 °C (14 to 104°F) and a humidity of 10 to 80%
5 The product must be kept dry at all times. The humid surrounding environment may affect the service life of the product or even damage the product
6 Please handle the used battery according to the laws and regulations of the local government